![IXYS zilog Z51F6412 Manual Download Page 152](http://html1.mh-extra.com/html/ixys/zilog-z51f6412/zilog-z51f6412_manual_2098946152.webp)
Z51F6412
Product Specification
PS030302-0212
P R E L I M I N A R Y
149
12.5.1 Register Map
Table 12-2 Register Map
Name
Address
Dir
Default
Description
PCON 87H
R/W
00H Power
Control
Register
12.5.2 Power Down Operation Register description
The Power Down Operation Register consists of the Power Control Register (PCON).
12.5.3 Register description for Power Down Operation
PCON (Power Control Register) : 87H
7
6
5
4
3
2
1
0
BIT7
BIT6
BIT5
BIT4
BIT3
BIT2
BIT1
BIT0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Initial value : 00H
IDLE Mode
01H
IDLE mode enable
STOP1, 2 Mode
03H
STOP1, 2 mode enable
Note)
1. To enter IDLE mode, PCON must be set to ‘01H’.
2. To STOP1,2 mode, PCON must be set to ‘03H’.
(In STOP1,2 mode, PCON register is cleared automatically by interrupt or reset)
3. When PCON is set to ‘03H’, if SCCR[7] is set to ‘1’, it enters the STOP1 mode. if SCCR[7] is cleared to
‘0’, it enters the STOP2 mode
4. The different thing in STOP 1,2 is only clock operation of internal 125kHz-OSC during STOP mode
operating.