DIGISPENSE 3020 CONTROLLER MODULE
Page 3-72
7 April, 2011
IVEK Corp.
P03L011B
Prod Dwells Screen Description -
The Prod Dwells screen displays the production dwell time information and allows
a user with Supervisor permission to change the parameters. The current permission level determines which push-
buttons are available as shown.
The Start push-button is not functional, but the Stop push-button is functional while this screen is visible.
Status -
The status indicates the operational state of the system. Refer to section 3.3.9 for an explanation of each
status type.
Pre-Op Dwell -
The Pre-Op Dwell indicates the delay time in seconds between a logic signal transition or Start and
pump operation in Production mode. The range is 0.00 seconds to 2.55 seconds with an increment value of 0.01.
(Refer to section 3.3.1.6)
Post-Op Dwell -
The Post-Op Dwell indicates the time in seconds from the end of a production operation and the
logic output signal becomes inactive. The range is 0.00 seconds to 2.55 seconds with an increment value of 0.01.
(Refer to section 3.3.1.6)
To change a value;
1. Press the Arrow push-buttons to highlight the parameter.
2. Press the Enter push-button to bring up either the Select New Value or Enter New Value screen.
3. In the Select New Value screen use the up and down arrow push-buttons to select the value. In the Enter New
Value screen press the Minimum or Maximum push-buttons to select the desired value or use the left and right
arrow push-buttons to select the digit and the up and down arrow push-buttons to change the digit's value.
4. Press the Enter push-button.