DIGISPENSE 3020 CONTROLLER MODULE
Page 3-66
7 April, 2011
IVEK Corp.
P03L011B
Setup C Screen Description -
The Setup C screen displays some additional settings for the Controller Module and
allows a user with Supervisor permission to change the parameters. The current permission level determines which
push-buttons are available as shown.
The Start push-button is not functional, but the Stop push-button is functional while this screen is visible.
Status -
The status indicates the operational state of the system. Refer to section 3.3.9 for an explanation of each
status type.
Pump -
The Pump setting displays the current pump size. This setting has to match the pump size on the Actuator for
the system to operate properly. The pump size can be either 4A, 3A, 2A, 1A, B, C, D or NONE.
Pump 90 Deg Offset -
The Pump may be offset 90 degrees relative to the actuator in order to achieve various
alignments of the inlet/outlet. Refer to section 3.1.7 for further explanation.
Encoder -
Selecting this value for change switches to the "Encoder" screen shown in section 3.3.8.16.
Active Port -
The active port indicates which port is the outlet in forward direction operations. The setting can either
be Port A or Port B. Refer to section 3.1.6 for additional information.
Valving Speed -
The Valving Speed is a percentage of the rate the piston flat moves between ports. The range is 1%
to 100% with an increment value of 1. Viscous fluids may require a value less than 100%.
Torque -
The Torque indicates the current torque setting for the motor. The setting can either be Low, Medium or
High. Refer to section 3.1.10 for additional information.
Acceleration -
Acceleration determines how fast the motor gets up to full speed when first started. The acceleration
can either be Slow, Medium, Standard and Fast. Standard acceleration should work for most applications and is the
system default value. Faster acceleration values, if combined with larger motor sizes or high viscosity fluids / large
displacement volumes, may cause nuisance faults. Refer to section 3.1.8 for additional information.
To change a value;
1. Press the Arrow push-buttons to highlight the parameter.
2. Press the Enter push-button to bring up either the Select New Value or Enter New Value screen.
3. In the Select New Value screen use the up and down arrow push-buttons to select the value. In the Enter New
Value screen press the Minimum or Maximum push-buttons to select the desired value or use the left and right
arrow push-buttons to select the digit and the up and down arrow push-buttons to change the digit's value.
4. Press the Enter push-button.