Table 3.4 Common Operational Problems And Solutions - Cont.
PROBLEM
PROBABLE
POSSIBLE SOLUTION
CAUSE
Backup Configuration Read Fault An error exists in backup
Reset parameters (WARNING: will reset all param-
copy of the configuration
eters and recipes)
data
The stored configuration
Cycle power.
data is corrupted.
Configuration Read Fault
The nonvolatile memory is
Reset parameters (WARNING: will reset all param-
corrupted.
eters and recipes)
Configuration Value Out of
A stored configuration data
Cycle power.
Bounds Fault
is corrupted.
Reset parameters (WARNING: will reset all param-
eters and recipes)
Configuration Version Fault
The stored configuration
Cycle power.
data has an unexpected
version
Reset parameters (WARNING: will reset all param-
eters and recipes)
Fluid dispensed during operation Pump size configured in
Make sure pump size configuration in controller
does not match setting
controller does not match
matches pump size attached to actuator.
actual pump size
If none of the above solves the problem,