Setup A Screen Description -
The Setup A screen displays some of the higher level settings for the Controller
Module and allows a user with Supervisor permission to change the parameters. The current permission level
determines which push-buttons are available as shown.
The Start push-button is not functional, but the Stop push-button is functional while this screen is visible.
Status -
The status indicates the operational state of the system. Refer to section 3.3.9 for an explanation of each
status type.
Recipe -
The Recipe line shows the current recipe selected in the Recipe screen. "0" indicates values changed
since last "Get Recipe".
Pump -
The Pump line shows the current pump size selected in the Setup C screen. The pump size can be either
4A, 3A, 2A, 1A, B, C, D or NONE.
Production Mode -
The Production Mode configures the current mode of operation. The mode can either be
Disabled, Dispense, Meter, Dispense MCV (Minimum Chamber Volume), Dispense Mult (Multichamber) or Meter
Mult (Multichamber). Refer to section 3.3.1 for description of advanced modes.
Fluidic Setup Mode -
The Fluidic Setup Mode configures the current mode of operation during setup. The mode can
either be Disabled, Prime, Bubble Clr (Clear) or Agitate. Refer to section 3.3.2 for description of Bubble Clear and Agitate.
Load Mode -
The Load Mode configures the current mode for refilling the pump chamber with fluid. The mode can
be either Manual, Empty or Every.
Auto Retrigger -
Refer to Section 3.3.8.14.
Production Dwells -
Refer to Section 3.3.8.15.
Power-Up Permission -
The Power-Up Permission configures the current setting for the permission when the
Controller Module is powered on. The mode can be either Operator or Last At Power Off.
Current-Permission -
Refer to Section 3.3.8.19.
To change a value;
1. Press the Arrow push-buttons to highlight the parameter.
2. Press the Enter push-button to bring up either the Select New Value or Enter New Value screen.
3. In the Select New Value screen use the up and down arrow push-buttons to select the value. In the Enter New
Value screen press the Minimum or Maximum push-buttons to select the desired value or use the left and right
arrow push-buttons to select the digit and the up and down arrow push-buttons to change the digit's value.
4. Press the Enter push-button.