DIGISPENSE 3020 CONTROLLER MODULE
Page 3-41
7 April, 2011
IVEK Corp.
P03L011B
Screen
Description
Agitate
Displays volume agitated, recipe # and pump size. Allows changing volume, discharge
rate, intake rate, agitate dwell time and isolation volume.
Auto Trig
Allows changing auto retrigger, auto dwell time, dispense count and reload count.
Bubble Clear
Displays recipe # and pump size. Allows changing the discharge rate, intake rate and
intake dwell time.
Change Password
Allows changing the password.
Change Permission
Allows changing the Permission level.
Clear Totalizer
Clears the total volume and total cycles counters.
Contrast Adjust
Allows changing the screen contrast. (not available on all units)
Dispense
Displays total volume, total cycles, recipe # and pump size. Allows changing direction,
dispense volume, dispense rate, load rate, load threashold and drawback settings.
Dispense MCV
Displays total volume, total cycles, recipe # and pump size. Allows changing direction,
dispense volume, dispense rate, load rate, MCV conserve fluid and drawback settings.
Dispense Mult
Displays total volume, total cycles, recipe # and pump size. Allows changing direction,
dispense volume, dispense rate, load rate and load threashold.
Drawback
Allows changing drawback volume, drawback rate and drawback dwell.
Encoder
Allows changing encoder and encoder lines.
Enter New Password
Used for changing an existing password.
Enter New Value
Used for entering a numerical value.
Fault
Displays the current fault.
I/O Test
Displays trigger in, input 2, CC trig in, input 3, input 4 and RS232. Allows
changing ready out, fault out, config 3 out, config 4 out and auxiliary out.
Meter
Displays total volume, total cycles, recipe # and pump size. Allows changing direction,
dispense rate, load rate, load threashold and drawback settings.
Meter Mult
Displays total volume, total cycles, recipe # and pump size. Allows changing direction,
dispense rate and load rate.
Prime
Displays volume primed, recipe # and pump size. Allows changing direction, volume,
discharge rate and intake rate.
Power Up
Displays the current recipe number and pump size.
Prod Dwells
Allows changing pre-op dwell and post-op dwell.
Recipe
Used for saving a new recipe or retrieving an existing recipe.
Reset Parameters Warnings
Erases all recipes and resets passwords.
Select New Value
Used for selecting a new value from a list.
Setup A
Displays recipe # and pump size. Allows changing production mode, fluidic setup
mode, load mode, auto retrigger, production dwells, power-up permission and
currentpermission.
Setup B
Displays output 2, input CC and input 1. Allows changing auxiliary output, ready output
config, output 3 config, output 4 config, input 2 config, input 3 config and input 4 config.
Setup C
Displays pump chamber volume.
Allows changing pump size, encoder, pump 90 degree
offset, active port, valving speed, torque and acceleration.
System Info
Displays firmware version, firmware CRC, serial number, asserts SW, Assert SW
code, asserts HW, asserts HW code.
Warning Recipe Exists
Appears when you try to save a recipe using a previously used number.