![IVEK DIGISPENSE 3020 Manual Download Page 103](http://html1.mh-extra.com/html/ivek/digispense-3020/digispense-3020_manual_2097276103.webp)
DIGISPENSE 3020 CONTROLLER MODULE
Page 3-103
7 April, 2011
IVEK Corp.
P03L011B
Command Response
Description
n98,<value2>n98,<value2>Saves the current values to specified recipe if recipe is blank.
<value2>:
Maximum:
32
Minimum:
1
n99,<value2>n99,<value2>Saves the current values to specified recipe and overwrites any existing recipe.
<value2>:
Maximum:
32
Minimum:
1
p => PORT
p or p0
p0,<value2> Returns the Active Port setting.
p0,<value2> p0,<value2> Sets the Active Port.
<value2>:
0 = Port A
1 = Port B (default)
p1
p1,<value2> Returns the Valving Speed percentage setting.
p1,<value2> p1,<value2> Sets the Valving Speed percentage.
<value2>:
Maximum:
100 (default)
Minimum:
1
p2
p2,<value2> Returns the Park Position
p2, <value2> p2,<value2> Sets the Park Position
Maximum: 359
Minimum:
0
Default:
180
p3
p3,<value2> Parks/unparks the Port
<value2>:
0 = unpark port
1 = park port
q => READY/BUSY
q or q0 q0,<value2> Indicates the current operation state.
<value2>:
0 = Idle
1 = Priming
2 = Dispensing
3 = Metering
4 = Drawback Dwell
5 = Drawback
6 = Fault
7 = Referencing
8 = Initializing (on power-up)
9 = Pre-op dwelling
10 = Post-op dwelling
11 = Auto dwelling
12 = Isolating (agitate mode)
13 = Agitating
14 = Returning (agitate mode)
15 = Bubble Clear
16 = Loading
17 = Porting (upon changing the active port setting)
18 = Agitate Dwelling
19 = Parking Port