DIGISPENSE 3020 CONTROLLER MODULE
Page 3-64
7 April, 2011
IVEK Corp.
P03L011B
Setup B Screen Description -
The Setup B screen displays some additional higher level settings for the Controller
Module and allows a user with Supervisor permission to change the parameters. The current permission level
determines which push-buttons are available as shown.
The Start push-button is not functional but the Stop push-button is functional while this screen is visible.
Status -
The status indicates the operational state of the system. Refer to section 3.3.9 for an explanation of each
status type.
Auxiliary Output -
The Auxiliary Output selects the logic for an additional output signal. The output signal can either
be Disabled, Enable Fluid Ops, Enable Both or Enable Prod Ops. Refer to section 3.3.10.2 for signal functions.
Ready Output Config -
The Ready Output Config sets the configuration of the Ready Output signal. The output
signal can be either Disabled, Busy Discharge, Busy Prod Only, Busy Moving, Ready Idle or Ready for Prod. Refer
to section 3.3.10.3 for signal functions.
Output 2 -
The Output 2 displays the setting for the 2nd output signal. This field is set to Fault Output and is not
changeable.
Output 3 Config -
The Output 3 Config settings determines the signal type for the 3rd output. The output signal can
be either Disabled, Busy Discharge, Busy Prod Only, Busy Moving, Ready Idle, Ready for Prod, Ref Required, Load
Required or Port Park. Refer to section 3.3.10.3 for signal functions.
Output 4 Config -
The Output 4 Config settings determines the signal type for the 4th output. The output signal can
be either Disabled, Busy Discharge, Busy Prod Only, Busy Moving, Ready Idle, Ready for Prod, Ref Required, Load
Required or Port Park. Refer to section 3.3.10.3 for signal functions.
Input CC -
The Input CC setting determines the signal type for the CC input. This setting is preset to Prod Mode
Trigger and is not changeable. Refer to section 3.3.10.1.
Input 1 -
The Input 1 setting determines the signal type for the 1st input. This setting is preset to Prod Mode Trigger
and is not changeable.
Input 2 Config -
The Input 2 Config settings determines the signal type for the 2nd input. The input signal can be
either Clear Fault & Reference, Fluid Mode trigger, Enable Motion, Load Trigger or Port Park. Refer to section
3.3.10.3 for signal functions.
Input 3 Config -
The Input 3 Config settings determines the signal type for the 3rd input. The input signal can be
either Clear Fault & Reference, Fluid Mode trigger, Enable Motion, Load Trigger or Port Park. Refer to section
3.3.10.3 for signal functions.
Input 4 Config -
The Input 4 Config settings determines the signal type for the 4th input. The input signal can be
either Clear Fault & Ref, Fluid Mode Trigger, Enable Motion, Load Trigger, EN FP RS, EN FP RS / VC, EN FP RS /
VC /PD, EN FP RG&S / VC, EN FP RG&S / VC /PD, EN FP RG&S / VC/PD/S. Refer to section 3.3.10.3 for signal
functions.
To change a value;
1. Press the Arrow push-buttons to highlight the parameter.
2. Press the Enter push-button to bring up either the Select New Value or Enter New Value screen.
3. In the Select New Value screen use the up and down arrow push-buttons to select the value. In the Enter New
Value screen press the Minimum or Maximum push-buttons to select the desired value or use the left and right
arrow push-buttons to select the digit and the up and down arrow push-buttons to change the digit's value.
4. Press the Enter push-button.