Technical Documentation
opti-check
v2.8.2-K11
151/332
ipf electronic GmbH
Lüdenscheid, Germany
The current number of distances calculated is displayed as
Number of distances
in the dialogue by
default.
You can also select which located distances should be counted. You can select whether to count the
number of distances within or outside of the tolerance range.
The switching points designated
Min
and
Max
are adjusted on the right hand side. A graphic display
is located in the middle, in which the positions of the switching points are displayed and where they
can be changed.
The button on the right inverts the result of the
Number of distances
partial check.
If you activate
Only count largest related group
, only the number of distances located within the
largest group will be counted
– i.e. the distances which fulfil the set criteria and appear directly next
to one another.
Methods:
Here you can define the methods the search beams should use to search for edges. The
search direction is indicated by a yellow arrow in the field of view.
The methods available depend
upon the shape of the field of view.
NOTE
For horizontal edge searches, you must rotate the field of view.
single:
The system searches for an edge in a single direction from each search beam position. The
reference point used to calculate the distance is the edge of the field of view (field of view alignment)
or the located reference line (object alignment).
double:
The system searches for an edge in two directions from each search beam position. The
distance between the two located edges on the search beam is calculated.