Technical Documentation
opti-check
v2.8.2-K11
23/332
ipf electronic GmbH
Lüdenscheid, Germany
1. Start the set-up program from the CD and follow the installation instructions.
2. A link to the
software
will be made on your desktop. The software is launched by double clicking on
this link.
3. Check the
network settings
to connect to the device.
When the device
has been correctly connected and the software is successfully installed, the Vision Sensor
can be commissioned using the software.
NOTE
You can launch the Application Suite using a command line parameter and automatically
connect to the device via an IP address.
Example:
appsuite2.exe /ip=192.168.0.250
(default IP address)
There is also the option to launch the
Application Suite
in different languages using a
command line parameter.
/l=de (German)
/l=en (English)
/l=fr (French)
Example:
appsuite2.exe /ip=192.168.0.250 /l=en
(Start the