15.3.5 Response delay
Signal
Duration
min.
max.
Response time T
1
No further commands must be transferred during
this time!
0 ms
max. { T
2
, T
3
} + T
4
Reaction time T
2
Ethernet
1 ms
5 ms
RS485
(device dependant)
1 ms
5 ms + 2.5 ms
per
128 bytes of data
Response delay T
3
T
2
10,000 ms
Transfer time T
4
dependant on the transfer parameters and the length of
the data
The transfer of the data begins not before time T
2
or the value set by the user.
If the time of the maximum response delay is exceeded without data being transferred, the possible
response is discarded and you can transfer further commands.
Please observe that the received command will be processed in any case, even if no response datagram has
been transferred due to the elapse of the maximum response time! For example, it is possible that this time
could be exceeded when switching the active job. In this case, you will receive no confirmation, although the
active job has been changed. If necessary, query the device status if you have received no confirmation.