Technical Documentation
opti-check
v2.8.2-K11
154/332
ipf electronic GmbH
Lüdenscheid, Germany
On the
Details
tab, there is a table showing the results for the individual search beams and a bar chart. This
tab is only used to display the values. You can zoom into the bar chart with the magnifying glass.
If you hover your cursor over one of the values in the table or a bar in the bar chart, the corresponding
search line, point or distance will be highlighted in the field of view.
If the feature check is to be corrected by the result of the part location, you can choose this option
here.
Confirm your settings and return to the feature list with
OK
. Return to the feature list without making
any changes with
Cancel
.
This feature check has the following output values for the datagram at the process interface:
Output value
Data type
Description
Result
Result of the feature check: "P" (Pass); "F" (Fail)
Number of distances
Float
Minimum distance
Float
Maximum distance
Float
Difference Max-Min
Float
Greatest difference
between adjacent
distances
Float
Mean distance
Float
Standard difference
Float
Distance list
Float list
Edge point A list
Float-Point
list
Intersection between search beam and located edge
X
–
separator
– Y, "NaN" if point is not found