If you have made your own settings, you may save them as a new profile.
Using this function, you can delete a profile that you created.
You have various operating modes available.
Operating Mode
Description
Deactivate illumination
No settings possible / illumination port deactivated
Steady light illumination
Settings possible (limit operating voltage/current)
Flash illumination
All settings possible
Control the external flash
controller
No settings possible, flash sync active
Control the external flash
controller (max. 1 ms)
No settings possible, flash sync active (max. 1 ms)
Control the external flash
controller (without limit)
No settings possible, flash sync synchronous to exposure
active
Here, you can define settings in the current operating mode.
Function
Setting Possibilities
Operating voltage of illumination:
12VDC/24VDC
Limit the current to:
Steady light illumination
0.1A…0.8A (increments of 0.1A)
Flash illumination
0.1A…4.0A (increments of 0.1A)
Maximum flash duration:
1µs…1000µs
Duty Cycle:
1%...10%