Technical Documentation
opti-check
v2.8.2-K11
144/332
ipf electronic GmbH
Lüdenscheid, Germany
If the feature check is to be corrected by the result of the part location, you can choose this option
here. External teach also makes it possible to retrain the feature check. Select the appropriate option
for this purpose.
Confirm your settings and return to the feature list with
OK
. Return to the feature list without making
any changes with
Cancel
.
This feature check has the following output values for the datagram at the process interface:
Output value
Data type
Description
Result
Result of the feature check: "P" (Pass); "F" (Fail)
Corner position
Float point
Coordinates of where the edges intersect
Angle of the corner
Float
Size of the angle between the edges (in degrees)
Position of corner
Float
Rotational position of edge 1 (in degrees, 0° ==
horizontal, 90° == vertical)
Distance
Float
Distance between the current corner position and
the corner position of the reference angle
Angle difference
Float
Difference between the current angle and the
reference angle (in degrees)
Deviation of position
Float
Difference between the current rotational position
and that of the reference angle (in degrees)