Technical Documentation
opti-check
v2.8.2-K11
65/332
ipf electronic GmbH
Lüdenscheid, Germany
Example
Output via the process interface of the data read from the
Spacing
feature check.
NOTE
The preview window on the right shows you in real time how your settings affect the data
to be transferred.
1.
Configure the
Distance
feature
check.
2.
Go to the
Configure interface → Output process interface
step.
3.
Configure all of the settings in the overview for the data output (see Data table
settings).
(1) Select the feature check / setting to be output.
(2) Select the value to be output.
(3) Set the start character, separator and end character for the datagram.
4.
Now the preview window on the
right will show how the data will be
output via the process interface.
The RD (
R
esponse
D
ata) and the
number of characters (4 byte
ASCII-Hex) will still be prefixed
(see RD Reply).
<Start>186.00<End>
5.
In this case the device would send
to the controller:
RD0013<Start>186.00<End>
(Note: 0013
HEX
= 19
DEZ
, length is therefore 19 characters)