15.5.2.4 Group: Parameters
This group is used to transfer parameter data for the current job. It is configured during job creation in the
Application Suite
in the step
Configure interfaces
→
Input process interface
.
Depending on the protocol variants are available with payload capacities of 4/8/16/32/64/128/256/512 bytes.
You should choose the smallest possible variants for the volume of data you expect to handle. An
unnecessarily large selection reduces overall system performance.
The data corresponds with the "SP" command in the classic process interface.
Data element
Direction
Type
Length
(byte)
Description
Actual length of
the parameters
PLC
device
UINT16
2
Length of data actually used in ParamData
Parameter (<n>
byte)
PLC
device
OCTET-
STRING
4/8/16/3
2/64/128
/256/512
Parameter data for the current job