Technical Documentation
opti-check
v2.8.2-K11
143/332
ipf electronic GmbH
Lüdenscheid, Germany
The current result is displayed directly in the dialogue as the angle. The switching points designated
Min
and
Max
are adjusted on the right hand side. A graphic display is located in the middle, in which
the positions of the switching points are displayed and where they can be changed.
The right button is used to invert the result of the feature check.
Select the calculation method and orientation of the angle.
Calculation method:
Angle between edges
: Angle between two edges
Angle to reference:
Angle to a reference edge
Orientation of the angle:
Smallest angle between edge A and B
Angle between edge A and B, clockwise
Angle between edge A and B, anticlockwise
You can teach in a new reference with this button.
Configure of the sensor as follows:
Min. edge length:
With short, medium or long, select the anticipated length of the sought contour to
achieve a consistent result. Using User defined, you may manually enter the length of an edge (5-
1000 pixels)
.
Transition:
You must specify whether each edge can progress from bright to dark or from dark to
bright (device dependant).
Minimum contrast:
You can also specify whether you are searching for an edge with sharp or weak
contrast.