Technical Documentation
opti-check
v2.8.2-K11
230/332
ipf electronic GmbH
Lüdenscheid, Germany
13.3 Timing for continuous image acquisition
The sequence of the individual signals and their designation are indicated in the diagram below:
Signal
Full resolution
Reduced resolution
(device dependant)
min.
max.
min.
max.
Exposure time T
2
Internal illumination
1
35
s
10 ms
35
s
5 ms
External illumination
35
s
1
/ 10
s
2
65.5 ms
35
s
1
/ 10
s
2
65.5 ms
Flash controller
2
10 µs
1 ms / 65.5 ms
10
s
1 ms
Image acquisition T
3
16 ms
20 ms
8 ms
11 ms
Output time (min / max) T
4
20 ms
11 ms
Run-up output T
5
50
s
2 ms
50
s
2 ms
Result retention time T
6
1 ms
1 s or next
result
1 ms
1 s or next
result
)
1
Devices with integrated lenses )
2
Devices with interchangeable lenses
If continuous image acquisition is set in the job, the image acquisition operation occurs as soon as the
previous image acquisition is complete. The
Camera Ready
signal is continuously activated during this time.
The Pass/Fail signal is switched at the end of image analysis but no earlier than the set output time. You can
recognize this time by a rising edge of the
Result valid
signal.