Technical Documentation
opti-check
v2.8.2-K11
56/332
ipf electronic GmbH
Lüdenscheid, Germany
In this dialogue, you can specify how the feature check results are to be logically linked together to produce
the result of the job.
You can specify one Total result and several Partial results for each job. In addition, it is possible to use the
Partial results for the configuration of the Total result.
It is possible to link the results with the following operations for configuration:
AND ("The results of all feature checks are OK.")
OR ("The result of at least one feature check is OK.")
You can also invert and ignore the result of a link by selecting the entry "NOK" or "Ignore" in column
"Nominal result".
It is possible to nest the links to any desired depth to achieve even more complex expressions. You can
insert new levels by selecting the "Insert expression" value in the context menu and then the appropriate
type of link. For each sub-link, you can now select the corresponding feature checks to be used for the
evaluation. Each feature check can appear any number of times in the overall expression, but only once at
each level.