Technical Documentation
opti-check
v2.8.2-K11
317/332
ipf electronic GmbH
Lüdenscheid, Germany
Example 2: Extensive configuration
– use of the modules "Control and status", "Result data (256 byte)",
"Parameters (128 byte)" and "Trigger data (64 byte)"
Input data (device
PLC)
Byte
Module
Data element
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
Control and
status
Handshake for
output data
pad (0)
C -> D
HS
ACK
pad (0)
C -> D
HSWA
ACT
ACK
C -> D
HSS
ACT
ACK
1
Handshake for
input data
pad (0)
D -> C
HS
Flag
pad (0)
D -> C
HSWA
ACT
ACK
D -> C
HSS
ACT
ACK
2
Device status
pad (0)
Img
Proc
ACT
Operating Mode
Teach
ACT
TRG
RDY
3
Current job
number
Active job number
4
pad (0)
5
Action status
pad (0)
Status SM
Status SP
Status SJ
6
Job results
pad (0)
Sub
Res 5
Fail
Sub
Res 5
Pass
7
Sub Res 4
Fail
Sub Res 4
Pass
Sub Res
3 Fail
Sub Res
3 Pass
Sub
Res 2
Fail
Sub
Res 2
Pass
Sub
Res 1
Fail
Sub
Res 1
Pass
8
pad (0)
9
pad (0)
Alarm
Total
Res
Fail
Total
Res
Pass
10
Device alarms
pad (0)
11
pad (0)
12
Alarm
PIF
HS Err
13
Alarm
PIF
Pipe OV
Alarm
PIF
Buf OV
Alarm
FTP
Alarm
PIF
Alarm
Inv
Job
Alarm
Output
Timeo
ut
Alarm
Inv
TRG
Alarm
(Any)
14
Result data
Handshake for
input data
pad (0)
D -> C
HS
Flag
pad (0)
D -> C
HSWA
ACT
ACK
D -> C
HSS
ACT
ACK
15
…
16
Actual
Length
Result data
Act Res Data Len
17
…
272
Result data
Result data (256 byte)
273
Parameters
Handshake for
output data
pad (0)
C -> D
HS
ACK
pad (0)
C -> D
HSWA
ACT
ACK
C -> D
HSS
ACT
ACK
274
Trigger data
Handshake for
output data
pad (0)
C -> D
HS
ACK
pad (0)
C -> D
HSWA
ACT
ACK
C -> D
HSS
ACT
ACK