Technical Documentation
opti-check
v2.8.2-K11
318/332
ipf electronic GmbH
Lüdenscheid, Germany
Output data (PLC
device)
Byte
Module
Data element
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
Control and
status
Handshake for
output data
pad (0)
C -> D
HS
Flag
pad (0)
C -> D
HSWA
ACT
C -> D
HSS
ACT
1
Handshake for
input data
pad (0)
D -> C
HS
ACK
pad (0)
D -> C
HSWA
ACT
D -> C
HSS
ACT
2
Device controller
pad (0)
Operating
mode
Teach
TRG
3
Job selection
Select job number
4
Reset statistics
Reset statistics
5
Reset status
(actions)
pad (0)
Reset
State SM
pad
(0)
Reset
State SP
pad (0)
Reset
State
SJ
6
Result data
Handshake for
input data
pad (0)
D -> C
HS
ACK
pad (0)
D -> C
HSWA
ACT
D -> C
HSS
ACT
7
Parameters
Handshake for
output data
pad (0)
C -> D
HS
Flag
pad (0)
C -> D
HSWA
ACT
C -> D
HSS
ACT
8 …
9
Actual
length of the
Parameters
Act Parameters Len
10
…
137
Parameters
Parameters (128 byte)
138
Trigger data
Handshake for
output data
pad (0)
C -> D
HS
Flag
pad (0)
C -> D
HSWA
ACT
C -> D
HSS
ACT
139
Actual length of
the trigger data
Act Trigger Data Len
140
…
203
Trigger data
Trigger data (64 byte)