Goodrive300-19 series open loop vector inverter special for hosit Function parameters
-102-
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
P11.09
Overload
pre-alarm
detection
Setting range of P11.08:
Enable and define the overload pre-alarm of the
inverter or the motor.
Setting range: 0x000~0x131
LED ones:
0: Overload pre-alarm of the motor, relative to the
rated current of the motor
1: Overload pre-alarm of the inverter, relative to the
rated current of the inverter
LED tens:
0: The inverter continues to work after underload
pre-alarm
1: The inverter continues to work after underload
pre-alarm and the inverter stops to run after overload
fault
2: The inverter continues to work after overload
pre-alarm and the inverter stops to run after
underload fault
LED hundreds :
0: Detection all the time
1: Detection in constant running
Setting range of P11.09: P11.11~200%
Setting range of P11.10: 0.1~3600.0s
150%
○
P11.10
Overload
pre-alarm
detection
time
1.0s
○
P11.11
Underload
pre-alarm
If the inverter current or the output current is lower
than P11.11, and its lasting time is beyond P11.12,
50%
○