Goodrive300-19 series open loop vector inverter special for hosit Installation guidelines
-20-
Environment
Conditions
to increase the internal temperature, otherwise damage to the devices
may occur.
Humidity
RH<90%
No condensation is allowed.
The maximum relative humility should be equal to or less than 60% in
corrosive air.
Storage
temperature
-30~+60°C
Running environment
condition
The installation site of the inverter should:
keep away from the electromagnetic radiation source;
keep away from contaminative air, such as corrosive gas, oil mist and
flammable gas;
ensure foreign objects, such as metal power, dust, oil, water can not
enter into the inverter (do not install the inverter on the flammable
materials such as wood);
keep away from radioactive and flammable materials;
keep away from harmful gas and liquids;
be in sites with little salt;
keep away from direct sunlight.
Altitude
<1000m
If the sea level is above 1000m, please derate 1% for every additional
100m.
Vibration
≤5.8m/s
2
(0.6g)
Installation direction
The inverter should be installed on an upright position to ensure
sufficient cooling effect.
Note:
Goodrive300-19 series inverters should be installed in a clean and ventilated
environment according to enclosure classification.
Cooling air must be clean, free from corrosive materials and electrically conductive dust.
4.2.2
Installation direction
The inverter may be installed on the wall or in a cabinet.
The inverter must be installed in an upright position. Check the installation site according to the
requirements below.
Refer to chapter
Dimension drawings
in the appendix for frame details.