Goodrive300-19 series open loop vector inverter special for hosit Communication protocol
-222-
Function
instruction
Address
definition
Data meaning instruction
R/W
characteristics
high-speed pulse 2
Read the current
stage of multi-step
speed
3012H
0~15
R
Reserved
3013H
0~65535
R
Reserved
3014H
0~65535
R
Torque setting
3015H
-300.0~300.0% (unit:
0.1%)
R
Identifying code of
the inverter
3016H
R
Fault code
5000H
R
R/W characteristics means the function is with read or write characteristic. For example,
“communication control command” is writing characteristic and control the inverter with writing
command (06H). R characteristic can only read other than write and W characteristic can only write
other than read.
Note:
when operating the inverter with the table above, it is necessary to enable some parameters.
For example, the operation of running and stopping, it is necessary to set P00.01 to communication
running command channel.
The encoding rules for device codes (corresponds to identifying code 2103H of the inverter)
High 8 bit
Meaning
Low 8 bit
Meaning
01
GD
0x08
GD35 vector inverter
0x09
GD35-H1 vector inverter
0x0a
GD300 vector inverter
0x0b
GD100 simple vector inverter
0x0c
GD200 universal inverter
0x0d
GD10 mini inverter
0x0e
GD800 PWM rectifier
0x0f
GD800 PWM inverter
0x1a
GD300-19 open loop vector inverter special for hoist
10.4.5 Fieldbus ratio values
The communication data is expressed by hex in actual application and there is no radix point in hex.
For example, 50.12Hz cannot be expressed by hex, so 50.12 can be magnified by 100 times into