Goodrive300-19 series open loop vector inverter special for hosit Peripherial options and parts
-250-
C.8.1.1 AC 3PH 380V(-15%)~440V(+10%)
Goodrive300-19 inverters of 380V (
≤55kW) have embedded braking units but the inverters of 380V
(
≥75kW) have optional braking units. Please select the resistance and power of the braking resistor
according to actual operation (the requirements of braking torque and usage ratio).
Inverter model
Model of braking
unit
Braking
resistance
at 100% of
the
braking
torque (
Ω
)
The cousumped power of the
braking resistor
Min.
allowable
braking
resistance
(
Ω)
10%
braking
50%
braking
80%
braking
GD300-19-1R5G-4
Embedded
braking units
326
0.23
1.1
1.8
170
GD300-19-2R2G-4
222
0.33
1.7
2.6
130
GD300-19-004G-4
122
0.6
3
4.8
80
GD300-19-5R5G-4
89
0.75
4.1
6.6
60
GD300-19-7R5G-4
65
1.1
5.6
9
47
GD300-19-011G-4
44
1.7
8.3
13.2
31
GD300-19-015G-4
32
2
11
18
23
GD300-19-018G-4
27
3
14
22
19
GD300-19-022G-4
22
3
17
26
17
GD300-19-030G-4
16
5
23
36
17
GD300-19-037G-4
13
6
28
44
11.7
GD300-19-045G-4
10
7
34
54
7
GD300-19-055G-4
8
8
41
66
GD300-19-075G-4 DBU100H-110-4
6.5
11
56
90
6.4
GD300-19-090G-4
DBU100H-160-4
5.4
14
68
108
4.4
GD300-19-110G-4
4.5
17
83
132
GD300-19-132G-4 DBU100H-220-4
3.7
20
99
158
3.2
GD300-19-160G-4
DBU100H-320-4
3.1
24
120
192
2.2
GD300-19-185G-4
2.8
28
139
222
GD300-19-200G-4
2.5
30
150
240
GD300-19-220G-4
DBU100H-400-4
2.2
33
165
264
1.8
GD300-19-250G-4
2.0
38
188
300
GD300-19-280G-4
Two
DBU100H-320-4
3.6*2
21*2
105*2
168*2
2.2*2
GD300-19-315G-4
3.2*2
24*2
118*2
189*2
Note:
Select the resistance and power of the braking resistor according to the data our company