Goodrive300-19 series open loop vector inverter special for hosit Function parameters
-68-
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
curve
setting
means of Goodrive300-19 motor 2 to meet various
requirements of different loads. See P04.00~P04.12
for the detailed function code instruction.
Note: P04 group includes two sets of V/F
parameters of the motor which cannot display
simultaneously and are only valid for the selected
motor. The motor selection can be selected by
defined channels in P08.31 or terminal function 35
“the shift between motor 1 and motor 2”.
P04.14
Torque
boost of
motor 2
0.0%
○
P04.15
Torque
boost close
of motor 2
20.0%
○
P04.16
V/F
frequency 1
of motor 2
0.00Hz
○
P04.17
V/F
voltage 1 of
motor 2
00.0%
○
P04.18
V/F
frequency 2
of motor 2
00.00Hz
○
P04.19
V/F
voltage 2 of
motor 2
00.0%
○
P04.20
V/F
frequency 3
of motor 2
00.00Hz
○
P04.21
V/F
voltage 3 of
motor 2
00.0%
○
P04.22
V/F slip
compensation
gain of motor
2
100.0%
○
P04.23
Vibration
control
factor at low
In SVPWM control mode, current fluctuation may
occur to the motor at some frequency, especially the
motor with big power. The motor cannot run stably or
10
○