![INVT Goodrive GD300-19-004G-4 Operation Manual Download Page 45](http://html1.mh-extra.com/html/invt/goodrive-gd300-19-004g-4/goodrive-gd300-19-004g-4_operation-manual_2085749045.webp)
Goodrive300-19 series open loop vector inverter special for hosit Function parameters
-44-
users can not modify the factory parameters by themselves, otherwise, if the parameter setting is
incorrect, damage to the inverter may occur). If the password protection is unlocked, the user can
modify the password freely and the inverter will work as the last setting one. When P07.00 is set to 0,
the password can be canceled. If P07.00 is not 0 during powering on, then the parameter is protected
by the password. When modify the parameters by serial communication, the function of the password
follows the above rules, too.
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
P00 Group Basic function group
P00.00
Speed
control
mode
1: Sensorless vector control mode 1
No need to install encoders. It is suitable in cases
with high speed control accuracy for accurate speed
and torque control at all power ratings.
2: SVPWM control mode
No need to install encoders. It can improve the control
accuracy with the advantages of stable operation,
valid low-frequency torque boost and current vibration
suppression and the functions of slip compensation
and voltage adjustment.
1
◎
P00.01
Running
command
channel
Select the running command channel of the inverter.
The control command of the inverter includes:
start-up, stop, forward, reverse, jogging and fault
reset.
0: Keypad running command channel
(“LOCAL/REMOT” light off)
Carry out the command control by RUN, STOP/RST
on the keypad.
Set the multi-function key QUICK/JOG to FWD/REV
shifting function (P07.02=3) to change the running
direction; press RUN and STOP/RST simultaneously
in running state to make the inverter coast to stop.
1: Terminal running command channel
(“LOCAL/REMOT” flickering)
Carry out the running command control by the
forward rotation, reverse rotation and forward jogging
and reverse jogging of the multi-function terminals
2: Communication running command channel
1
○