![INVT Goodrive GD300-19-004G-4 Operation Manual Download Page 140](http://html1.mh-extra.com/html/invt/goodrive-gd300-19-004g-4/goodrive-gd300-19-004g-4_operation-manual_2085749140.webp)
Goodrive300-19 series open loop vector inverter special for hosit Basic operation instruction
-139-
Ready
P00.01=0 (keypad control)
Set P00.15=1
(rotation autotuning)
Set P00.15=2
(static autotuning)
Set autotuning method
(P00.15)
Press “RUN” key to enter
into autotuning
Display“-END-”
In autotuning
Autotuning end
Note:
1. Set the motor parameters according to the name plate of the motor.
2. During the motor autotune, if rotation autotune is selected, de-couple the motor from the
load to make the motor in a static and empty state; otherwise, the result of autotune is
incorrect. The asynchronous motors can autotune the parameters of P02.06~P02.10.
3. During the motor autotune, if static autotune is selected, do not de-couple the motor from
the load. Because only some parameters of the motor are involved, the control performance is
not as better as the rotation autotune. The asynchronous motors can autotune the parameters
of P02.06~P02.10.
4. Motor autotune only involves the current motor. Switch the motor through P08.31 to carry
out the autotune on the other motor.
Relative parameters list:
Function
code
Name
Detailed instruction of parameters
Default
value
P00.01
Running
0: Keypad running command channel (LED off)
1