Goodrive300-19 series open loop vector inverter special for hosit Basic operation instruction
-120-
Function
code
Name
Detailed instruction of parameters
Default
value
asynchronous
motor 1
P02.03
Rated speed
of
asynchronous
motor 1
1~36000rpm
Depend
on model
P02.04
Rated voltage
of
asynchronous
motor 1
0~1200V
Depend
on model
P02.05
Rated current
of
asynchronous
motor 1
0.8~6000.0A
Depend
on model
P05.01~
P05.09
Multi-function
digital input
terminal
36: Shift the command to the keypad
37: Shift the command to the terminal
38: Shift the command to the communication
P07.01
Parameter
copy
The function code determines the manner of parameters
copy.
0: No operation
1: Upload the local function parameter to the keypad
2: Download the keypad function parameter to local
address (including the motor parameters)
3: Download the keypad function parameter to local
address (excluding the motor parameter of P02 and P12
group)
4: Download the keypad function parameters to local
address (only for the motor parameter of P02 and P12
group)
0
P07.02
QUICK/JOG
function
selection
0: No function
1: Jogging
2: Shift the display state by the shifting key
3: Shift between forward rotations and reverse rotations
1