Goodrive300-19 series open loop vector inverter special for hosit Function parameters
-80-
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
P06.14
AO1 output 0: Running frequency
1: Set frequency
2: Ramp reference frequency
3: Running rotation speed
4: Output current (relative to 2 times of the rated
current of the inverter)
5: Output current (relative to 2 times of the rated
current of the motor)
6: Output voltage
7: Output power
8: Set torque value
9: Output torque
10: AI1 input value
11: AI2 input value
12: AI3 input value
13: High-speed pulse HDI input value
14: Modbus communication set value 1
15: Modbus communication set value 2
16~21: Reserved
22:Torque current (relative to 3 times of the rated
current of the motor)
23: Pre-magnetizing current (relative to the rated
current of the motor)
24~30: Reserved
0
○
P06.15
AO2 output
1
○
P06.16
HDO
high-speed
pulse output
0
○
P06.17
Lower output
limit of AO1
The above function codes define the relative
relationship between the output value and analog
output. When the output value exceeds the range of
set maximum or minimum output, it will count
according to the low-limit or upper-limit output.
When the analog output is current output, 1mA equals
to 0.5V.
In different cases, the corresponding analog output of
100% of the output value is different. See each
0.0%
○
P06.18
Correspondin
g AO1 output
of lower limit
0.00V
○
P06.19
Upper output
limit of AO1
100.0%
○
P06.20
Correspondin
g AO1 output
10.00V
○