Goodrive300-19 series open loop vector inverter special for hosit Function parameters
-48-
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
frequency
“keypad setting”, the value of the function code is the
original setting one of the frequency data of the
inverter.
Setting range: 0.00 Hz~P00.03 (the Max. frequency)
P00.11
ACC time 1
ACC time means the time needed if the inverter
speeds up from 0Hz to the Max. One (P00.03).
DEC time means the time needed if the inverter
speeds down from the Max. Output frequency
(P00.03) to 0Hz.
Goodrive300-19 series inverters define four groups of
ACC/DEC time which can be selected by P05. The
factory default ACC/DEC time of the inverter is the
first group.
Setting range of P00.11 and P00.12: 0.0~3600.0s
Depend
on
model
○
P00.12
DEC time 1
Depend
on
model
○
P00.13
Running
direction
0: Runs at the default direction, the inverter runs in
the forward direction. FWD/REV indicator is off.
1: Runs at the reverse direction, the inverter runs in
the reverse direction. FWD/REV indicator is on.
Modify the function code to shift the rotation direction
of the motor. This effect equals to the shifting the
rotation direction by adjusting either two of the motor
lines (U, V and W). The motor rotation direction can
be changed by QUICK/JOG on the keypad. Refer to
parameter P07.02.
Note: When the function parameter restores to
the default value, the motor’s running direction
will restore to the factory default state, too. In
some cases it should be used with caution after
commissioning if the change of rotation direction
is disabled.
2: Forbid to run in reverse direction: It can be used in
some special cases if the reverse running is disabled.
0
○