Goodrive300-19 series open loop vector inverter special for hosit Basic operation instruction
-154-
AI2
P05.38
Corresponding
setting of the
lower limit of
AI2
-100.0%~100.0%
0.0%
P05.39
Upper limit of
AI2
P05.37~10.00V
10.00V
P05.40
Corresponding
setting of
the upper limit
of AI2
-100.0%~100.0%
100.0%
P05.41
AI2 input filter
time
0.000s~10.000s
0.100s
P05.42
Lower limit of
AI3
-10.00V~P05.44
-10.00V
P05.43
Corresponding
setting of the
lower limit of
AI3
-100.0%~100.0%
-100.0%
P05.44
Middle value of
AI3
P05.42~P05.46
0.00V
P05.45
Corresponding
middle setting
of AI3
-100.0%~100.0%
0.0%
P05.46
Upper limit of
AI3
P05.44~10.00V
10.00V
P05.47
Corresponding
setting of
the upper limit
of AI3
-100.0%~100.0%
100.0%
P05.48
AI3 input filter
time
0.000s~10.000s
0.100s
P05.49
HDI
high-speed
pulse input
0: Frequency setting input
1~2: Reserved
0