Goodrive300-19 series open loop vector inverter special for hosit Function parameters
-71-
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
selection
5: Reverse jogging
6: Coast to stop
7: Fault reset
8: Operation pause
9: External fault input
10: Frequency setting increasing (UP)
11: Frequency setting decreasing (DOWN)
12: Frequency setting clear
13: Shift between A setting and B setting
14: Shift between combination setting and A setting
15: Shift between combination setting and B setting
16: Multi-step speed terminal 1
17: Multi-step speed terminal 2
18: Multi-step speed terminal 3
19: Multi-step speed terminal 4
20: Multi-step speed pause
21: ACC/DEC time 1
22: ACC/DEC time 2
23~28: Reserved
29:Torque control disabling
30: ACC/DEC disabling
31: Reserved
32: Reserved
33: Cancel the frequency change setting temporarily
34: DC brake
35: Shift the motor 1 to motor 2
36: Shift the command to the keypad
37: Shift the command to the terminal
38: Shift the command to the communication
39: Pre-magnetized command
40~56: Reserved
57: Inverter enabling
58: Contactor feedback signal
P05.03
S3 terminal
function
selection
7
◎
P05.04
S4 terminal
function
selection
0
◎
P05.05
S5 terminal
function
selection
0
◎
P05.06
S6 terminal
function
selection
0
◎
P05.07
S7 terminal
function
selection
0
◎
P05.08
S8 terminal
function
selection
0
◎
P05.09
HDI terminal
function
selection
0
◎