CHF100A series high performance universal inverter
.143.
Function
Code
Name
Description
Factory
Setting
Modify
Seri
al
No.
P7.14
Inverter rated
power
0-3000KW
Depen
ds
on
model
132
P7.15
Inverter rated
current
0.0-6000A
Depen
ds
on
model
133
P7.16
Accumulated
running time
0~65535h
●
134
P7.17
Third latest fault
type
●
135
P7.18
Second latest
fault type
●
136
P7.19
Latest fault type
0: Not fault
1: IGBT Ph-U fault(OUT1)
2: IGBT Ph-V fault(OUT2)
3: IGBT Ph-W fault(OUT3)
4: Over-current when
acceleration(OC1)
5: Over-current when
deceleration(OC2)
6:
Over-current
when
constant speed running
(OC3)
7: Over-voltage when
acceleration(OV1)
8: Over-voltage when
deceleration(OV2)
9:
Over-voltage
when
constant
speed
running(OV3)
10:
DC
bus
Under-voltage(UV)
11: Motor overload (OL1)
12:
Inverter
overload
(OL2)
13: Input phase failure
●
137