CHF100A series high performance universal inverter
.150.
Function
Code
Name
Description
Factory
Setting
Modify
Seri
al
No.
PB.02
Motor overload
protection
0: Disabled
1: Normal motor
2:
Variable
frequency
motor
2
¥
223
PB.03
Motor overload
protection current
20.0% ~ 120.0% (rated
current of the motor)
100.0%
O
224
PB.04
Threshold of
trip-free
70.0.0~110.0% (standard
bus voltage)
80.0%
O
225
PB.05
Decrease rate of
trip-free
0.00Hz~P0.03
0.00Hz
O
226
PB.06
Over-voltage stall
protection
0: Disabled
1: Enabled
1
O
227
PB.07
Over-voltage stall
protection point
110~150%
380V:
130%
220V:
120%
O
228
PB.08
Auto current
limiting threshold
50~200%
G Model:
160%
P Model:
120%
O
229
PB.09
Frequency
decrease rate
when current
limiting
0.00~50.00Hz/s
10.00Hz/s
O
230
PB.10
Auto current
limiting selection
0: Enabled
1: Disabled when constant
speed
0
O
231