CHF100A series high performance universal inverter
.86.
Figure 6.29 Multi-steps speed operation diagram.
Terminal
Step
Multi-step
speed
reference1
Multi-step
speed
reference2
Multi-step
speed
reference3
Multi-step
speed
reference4
0
OFF
OFF
OFF
OFF
1
ON
OFF
OFF
OFF
2
OFF
ON
OFF
OFF
3
ON
ON
OFF
OFF
4
OFF
OFF
ON
OFF
5
ON
OFF
ON
OFF
6
OFF
ON
ON
OFF
7
ON
ON
ON
OFF
8
OFF
OFF
OFF
ON
9
ON
OFF
OFF
ON
10
OFF
ON
OFF
ON
11
ON
ON
OFF
ON
12
OFF
OFF
ON
ON
13
ON
OFF
ON
ON
14
OFF
ON
ON
ON
15
ON
ON
ON
ON
Function
Code
Name
Description
Setting
Range
Factory
Setting
PA.34
ACC/DEC
time selection
for step 0~7
0~0XFFFF
0~0XFFFF
0