CHF100A series high performance universal inverter
.50.
Under speed control model, output torque matches load torque automatically, but limited
by P3.07.
Under torque control model, output torque is limited by upper and lower frequency limit.
Notice:
l
speed control and torque control can be switched by using multi-function
input terminals.
l
1~5
:
100% corresponding to twice of rated current of inverter.
l
When inverter decelerate to stop, Torque control model is switched to speed
control mode automatically
Function
Code
Name
Description
Setting Range
Factory
Setting
P3.09
Keypad
torque
setting
-200.0%~200.0%
-200.0%~200.0%
50.0%
P3.10
Upper
frequency
setting
source
0: Keypad
(
P0.04
)
1: AI1
2: AI2
3: HDI
4: Multi-step
5: Communication
0~5
0
Notice: 1~4 100% Corresponding to maximum frequency.
6.5 P4 Group
—
V/F Control
Function
Code
Name
Description
Setting
Range
Factory
Setting
P4.00
V/F curve
selection
0:Linear V/F curve
1: User-defined curve
2: Torque_stepdown curve
(1.3 order)
3: Torque_stepdown curve
(1.7 order)
4: Torque_stepdown curve
(2.0 order)
0~4
0
0: Linear V/F curve. It is applicable for normal constant torque load.
1: User-defined curve. It can be defined through setting (P4.03~P4.08).
Summary of Contents for CHF100A-004G-2
Page 1: ......
Page 4: ......
Page 10: ......
Page 11: ......
Page 13: ......
Page 14: ......
Page 59: ......
Page 60: ......
Page 98: ......
Page 100: ......
Page 103: ......
Page 121: ...CHF100A series high performance universal inverter 120 Figure A 16 Open inverter cabinet ...
Page 155: ......
Page 156: ......