CHF100A series high performance universal inverter
.54.
restraining oscillation.When the running frequency is lower than P4.13, P4.11 is valid,
when the running frequency higher than P4.13, P4.12 is valid.
6.6 P5 Group--Input Terminals
Function
Code
Name
Description
Setting
Range
Factory
Setting
P5.00
HDI selection
0: High speed pulse input
1: ON-OFF input
0~1
0
P5.01
S1 terminal
function
Programmable multifunctional
terminal
0~39
1
P5.02
S2 terminal
function
Programmable multifunctional
terminal
0~39
4
P5.03
S3 terminal
function
Programmable multifunctional
terminal
0~39
7
P5.04
S4 terminal
function
Programmable multifunctional
terminal
0~39
0
P5.05
S5 terminal
function
Programmable multifunctional
terminal
0~39
0
P5.06
S6 terminal
function
Programmable multifunctional
terminal
0~39
0
P5.07
S7 terminal
function
Programmable multifunctional
terminal
0~39
0
P5.08
HDI
terminal
function
Programmable multifunctional
terminal
0-39
0
Notice: P5.08 is only used when P5.00 is set to be 1.
The meaning of each setting is shown in following table.
Setting
value
Function
Description
0
Invalid
Please set unused terminals to be invalid to avoid
malfunction
1
Forward
2
Reverse
Please refer to description of P5.10.
3
3-wire control
Please refer to description of P5.10.
4
Jog forward
5
Jog reverse
Please refer to description of P8.06~P8.08.
6
Coast to stop
The inverter blocks the output immediately. The motor
Summary of Contents for CHF100A-004G-2
Page 1: ......
Page 4: ......
Page 10: ......
Page 11: ......
Page 13: ......
Page 14: ......
Page 59: ......
Page 60: ......
Page 98: ......
Page 100: ......
Page 103: ......
Page 121: ...CHF100A series high performance universal inverter 120 Figure A 16 Open inverter cabinet ...
Page 155: ......
Page 156: ......