CHF100A series high performance universal inverter
.139.
Function
Code
Name
Description
Factory
Setting
Modify
Seri
al
No.
P6.04
AO1 function
selection
0
O
103
P6.05
AO2 function
selection
0: Running frequency
1: Reference frequency
2: Motor speed
3: Output current
4: Output voltage
5: Output power
6: Output torque
7: AI1 voltage
8: AI2 voltage/current
9: HDI frequency
0
104
P6.06
Reserved
Reserved
0
O
105
P6.07
AO1 lower limit
0.0%~100.0%
0.0%
O
106
P6.08
AO1 lower limit
corresponding
output
0.00V ~10.00V
0.00V
O
107
P6.09
AO1 upper limit
0.0%~100.0%
100.0%
O
108
P6.10
AO1 upper limit
corresponding
output
0.00V ~10.00V
10.00V
O
109
P6.11
AO2 lower limit
0.0~100.0%
0.0%
110
P6.12
AO2 lower limit
corresponding
output
0~10.00V
0.00V
111