Function
Code
Name
Description
Factory
Setting
Modify
Seri
al
No.
P7.06
Running status
display selection 1
0~0XFFFF
BIT0: running frequency
BIT1:
Reference
frequency
BIT2: DC bus voltage
BIT3: Output voltage
BIT4: Output current
BIT5: Rotation speed
BIT6: Line speed
BIT7: Output power
BIT8: Output torque
BIT9: PID preset
BIT10: PID feedback
BIT11:
Input
terminal
status
BIT12: Output terminal
status
BIT13:
Torque
setting
value
BIT14: Count value
BIT15: Step No. of PLC or
multi-step
0X07FF
O
124
P7.07
Running status
display selection 2
0~0XFFFF
BIT0: AI1
BIT1: AI2
BIT2: HDI frequency
BIT3: Load percentage of
motor
BIT4: Load percentage of
inverter
BIT
5:
Accumulated
running time
0X0000
O
125