Function
Code
Name
Description
Setting
Range
Factory
Setting
PA.35
ACC/DEC
time selection
for step 8~15
0~0XFFFF
0~0XFFFF
0
These parameters are used to determine the ACC/DEC time from one step to next step.
There are four ACC/DEC time groups.
Function
Code
Binary Digit
Step
No.
ACC/DEC
Time 0
ACC/DEC
Time 1
ACC/DEC
Time 2
ACC/DEC
Time 3
BIT1
BIT0
0
00
01
10
11
BIT3
BIT2
1
00
01
10
11
BIT5
BIT4
2
00
01
10
11
BIT7
BIT6
3
00
01
10
11
BIT9
BIT8
4
00
01
10
11
BIT11
BIT10
5
00
01
10
11
BIT3
BIT12
6
00
01
10
11
PA.34
BIT15
BIT14
7
00
01
10
11
BIT1
BIT0
8
00
01
10
11
BIT3
BIT2
9
00
01
10
11
BIT5
BIT4
10
00
01
10
11
BIT7
BIT6
11
00
01
10
11
BIT9
BIT8
12
00
01
10
11
BIT11
BIT10
13
00
01
10
11
BIT3
BIT12
14
00
01
10
11
PA.35
BIT15
BIT14
15
00
01
10
11
For example: To set the acceleration time of following table:
Step No.
0 1 2 3 4 5 6 7 8 9
10
11
12
13
14
15
ACC/DEC
time group
0 1 2 3 2 1 3 0 3 3
2
0
0
0
2
2
The value of every bit of PA.34 and PA.35 is:
Low byte
BIT 0
BIT 1
BIT 2
BIT 3
BIT 4
BIT 5
BIT 6
BIT 7
PA.34
0
0
1
0
0
1
1
1
PA.35
1
1
1
1
0
1
0
0
Summary of Contents for CHF100A-004G-2
Page 1: ......
Page 4: ......
Page 10: ......
Page 11: ......
Page 13: ......
Page 14: ......
Page 59: ......
Page 60: ......
Page 98: ......
Page 100: ......
Page 103: ......
Page 121: ...CHF100A series high performance universal inverter 120 Figure A 16 Open inverter cabinet ...
Page 155: ......
Page 156: ......