CHF100A series high performance universal inverter
.73.
Notice:
l
If P8.11 is 0, the skip function is invalid.
l
If both P8.09 and P8.10 are 0, the skip function is invalid no matter what
P8.11 is.
l
Operation is prohibited within the skip frequency bandwidth, but changes
during acceleration and deceleration are smooth without skip.
The relation between output frequency and reference frequency is shown in following
figure.
Figure 6.17 Skip frequency diagram.
Function
Code
Name
Description
Setting
Range
Factory
Setting
P8.12
Traverse
amplitude
0.0~100.0%
0.0~100.0
0.0%
P8.13
Jitter
frequency
0.0-50.0%
0.0-50.0
0.0%
P8.14
Rise time of
traverse
0.1-3600.0s
0.1-3600.0
5.0s
P8.15
Fall time of
traverse
0.1-3600.0s
0.1-3600.0
5.0s
Traverse operation is widely used in textile and chemical fiber industry. The typical
application is shown in following figure.