12000 Series CLI
True Scale Fabric Switches 12000 Series CLI
Reference Guide
July 2015
86
Options
<node index>
–
The node index of the switch to print the switch LFT..
Sample Output
-> XEdge-> smLooptestShowSwitchLft
Node[0000] LID=0x0001 GUID=0x00066a00e3002711 [Intel 12200
GUID=0x00066a00e3002711] Linear Forwarding Table
LID PORT
------ ----
0x0001 0000
0x0005 0031
0x0009 0017
0x0010 0011
0x0016 0021
0x001d 0022
0x0021 0025
0x0040 0009
0x0041 0033
0x0042 0033
0x0043 0009
Notes
Use this command to print the switch LFT specified by the switch index, or all switches
(default) for the SM Loop Test.
2.5.5.65
smLooptestShowTopology
Displays the topology for the SM Loop Test.
Syntax
smLooptestShowTopology
Options
None.
Sample Output
-> XEdge-> smLooptestShowTopology
sm_state = MASTER count = 481 LMC = 0, Topology Pass count = 4, Priority = 0,
Mkey = 0x0000000000000000
----------------------------------------------------------------------------------
-------
Intel 12200 GUID=0x00066a00e3002711
----------------------------------------------------------------------------------
-------