LGA775 Socket Heatsink Loading
60
Thermal and Mechanical Design Guidelines
6.2
Board and System Implementation of
Intel
®
Quiet System Technology
To implement the board it must be configured as shown in Figure 23 and listed in the
following bullets.
•
ME system (S0-S1) with Controller Link connected and powered
•
DRAM with Channel A DIMM 0 installed and 2 MB reserved for Intel QST FW
execution
•
SPI Flash with sufficient space for the Intel QST Firmware
•
SST-based thermal sensors to provide board thermal data for Intel QST algorithms
•
Intel QST firmware
Figure 23. Intel
®
Quiet System Technology Platform Requirements
Processor
ME
SPI
Flash
Intel®
ICH8
DRAM
Controller Link
DRAM
FSC
Control
SPI
SST
Sensor
Intel® (G)MCH
ME
Note:
Simple Serial Transport (SST) is a single wire bus that is included in the ICH8 to
provide additional thermal and voltage sensing capability to the Manageability Engine
(ME)