SAN32M1 Fabric Switch Installation and Service Manual
462
Event Code: 433
Message:
Non-recoverable Ethernet fault
Severity:
Major
Explanation:
A non-recoverable error condition was detected on the Ethernet adapter, and the LAN interface has been
shutdown. The connection to the EFC Server is terminated, but all Fibre Channel switching functions remain
unaffected. Since communication with the EFC Server is lost, no failure indication can be reported.
Action:
Replace the switch. Perform the data collection procedure for the switch using the EFC Manager, and return the
CD and the faulty CTP card to IBM for analysis and repair.
Event Data:
Bytes 0-3: LAN error type
01 = Hard failure - See LAN error subtype for reason.
04 = Registered fault - See LAN Fault ID for reason.
Bytes 4-7: LAN error subtype (Description of failure). Engineering use only.
Bytes 8-11: LAN fault identifier (Internally defined). Engineering use only.
Distribution:
Switch
EFC Server
Host
Nonvolatile
System
Event Log
System
Error
Indicator
Event Log
Call-Home
Sense Info
Link Incident
✔
✔
✔
Summary of Contents for SAN32M1
Page 1: ...IBM TotalStorage SAN32M1 Switch Installation and Service Manual GC26 7665 01...
Page 2: ......
Page 3: ...IBM TotalStorage SAN32M1 Switch Installation and Service Manual GC26 7665 01...
Page 12: ...SAN32M1 Fabric Switch Installation and Service Manual x...
Page 18: ...SAN32M1 Fabric Switch Installation and Service Manual xvi...
Page 20: ...SAN32M1 Fabric Switch Installation and Service Manual xviii...
Page 82: ...SAN32M1 Fabric Switch Installation and Service Manual 50...
Page 222: ...SAN32M1 Fabric Switch Installation and Service Manual 190...
Page 418: ...SAN32M1 Fabric Switch Installation and Service Manual 386...
Page 454: ...SAN32M1 Fabric Switch Installation and Service Manual 422...
Page 532: ...SAN32M1 Fabric Switch Installation and Service Manual 500...
Page 536: ...SAN32M1 Fabric Switch Installation and Service Manual 504...
Page 625: ......
Page 626: ...Printed in USA GC26 7665 01...