Chapter 5: FRU removal and replacement
Replacement
To replace a cooling fan FRU:
1. Remove the replacement cooling fan FRU from its shipping
container.
2. Inspect the rear of the fan FRU for bent or broken connector pins.
If any pins are damaged, obtain a new fan FRU.
3. Position the fan FRU with its retaining screw at the upper right
corner (the fan cannot be inserted in any other position).
4. Push the fan FRU into the chassis to engage the connector pins.
Ensure that the fan FRU faceplate is flush with the chassis.
5. Engage the threads of the retaining screw and lightly tighten the
screw. Over-tightening the screw may damage the FRU or chassis.
6. Inspect the fan FRU to ensure that the amber LED is extinguished.
If the amber LED is illuminated, go to
MAP 0000: Start MAP
on
page 195 to isolate the problem.
7. At the EFC Server’s Hardware View, select Event Log from the Logs
menu. The Event Log displays. Ensure one of the following event
codes appears in the log:
— 310 to 315 - Nth cooling fan has recovered, where N is First to
Sixth (fan).
8. At the EFC Server’s Hardware View, observe the fan graphic and
ensure no alert symbols appear that indicate a failure (yellow
triangle or red diamond). If a problem is indicated, go to
MAP
0000: Start MAP
on page 195 to isolate the problem.
9. Perform the data collection procedure (
Collecting maintenance data
on page 340).
10. Clear the switch system error (ERR) LED:
a. At the EFC Server’s Hardware View, right-click the front panel
bezel graphic (away from a FRU) to open a pop-up menu.
b. Click Clear System Error Light.
Summary of Contents for SAN32M1
Page 1: ...IBM TotalStorage SAN32M1 Switch Installation and Service Manual GC26 7665 01...
Page 2: ......
Page 3: ...IBM TotalStorage SAN32M1 Switch Installation and Service Manual GC26 7665 01...
Page 12: ...SAN32M1 Fabric Switch Installation and Service Manual x...
Page 18: ...SAN32M1 Fabric Switch Installation and Service Manual xvi...
Page 20: ...SAN32M1 Fabric Switch Installation and Service Manual xviii...
Page 82: ...SAN32M1 Fabric Switch Installation and Service Manual 50...
Page 222: ...SAN32M1 Fabric Switch Installation and Service Manual 190...
Page 418: ...SAN32M1 Fabric Switch Installation and Service Manual 386...
Page 454: ...SAN32M1 Fabric Switch Installation and Service Manual 422...
Page 532: ...SAN32M1 Fabric Switch Installation and Service Manual 500...
Page 536: ...SAN32M1 Fabric Switch Installation and Service Manual 504...
Page 625: ......
Page 626: ...Printed in USA GC26 7665 01...