429
Appendix B: Event code tables
Event Code: 061
Message:
Fabric Controller database found to be invalid
Severity:
Minor
Explanation:
Following an IML, CTP hot-plug, CTP failover, or LIC load, a Fabric Controller database failed its validation. All
Fabric Services databases are initialized to an empty state resulting in a momentary loss of inter-switch
communications.
Action:
Perform the data collection procedure for the switch using the EFC Manager, and return the CD to IBM for
analysis.
Event Data:
No supplementary data included with this event.
Distribution:
Switch
EFC Server
Host
Nonvolatile
System
Event Log
System
Error
Indicator
Event Log
Call-Home
Sense Info
Link Incident
✔
✔
✔
✔
✔
Event Code: 062
Message:
Maximum interswitch hop count exceeded
Severity:
Informational
Explanation:
The Fabric Controller software has detected that a path to another switch in the fabric traverses more than seven
interswitch links (‘hops’). This may result in frames persisting in the fabric longer than the Fibre Channel standard
timeout values allow.
Action:
If possible, reconfigure the fabric so that the path between any two switches traverses no more than seven
interswitch links.
Event Data:
Byte 0 = domain ID of the switch more than seven hops away.
Bytes 1 - 3 = reserved.
Distribution:
Switch
EFC Server
Host
Nonvolatile
System
Event Log
System
Error
Indicator
Event Log
Call-Home
Sense Info
Link Incident
✔
✔
Summary of Contents for SAN32M1
Page 1: ...IBM TotalStorage SAN32M1 Switch Installation and Service Manual GC26 7665 01...
Page 2: ......
Page 3: ...IBM TotalStorage SAN32M1 Switch Installation and Service Manual GC26 7665 01...
Page 12: ...SAN32M1 Fabric Switch Installation and Service Manual x...
Page 18: ...SAN32M1 Fabric Switch Installation and Service Manual xvi...
Page 20: ...SAN32M1 Fabric Switch Installation and Service Manual xviii...
Page 82: ...SAN32M1 Fabric Switch Installation and Service Manual 50...
Page 222: ...SAN32M1 Fabric Switch Installation and Service Manual 190...
Page 418: ...SAN32M1 Fabric Switch Installation and Service Manual 386...
Page 454: ...SAN32M1 Fabric Switch Installation and Service Manual 422...
Page 532: ...SAN32M1 Fabric Switch Installation and Service Manual 500...
Page 536: ...SAN32M1 Fabric Switch Installation and Service Manual 504...
Page 625: ......
Page 626: ...Printed in USA GC26 7665 01...