287
Chapter 3: Diagnostics
Figure 162
Configure fabric parameters dialog box
e. Type the recommended E_D_TOV and R_A_TOV values, then
click Activate.
f. Repeat steps d and e at the Hardware View for the switch
attached to the segmented switch. Use the same E_D_TOV and
R_A_TOV values.
g. Set both switches online (
Set online state
on page 350).
Did the operating parameter change solve the problem and did both
switches join through the ISL to form a fabric?
NO
YES
↓
The switches, associated ISL, and multiswitch fabric appear
operational.
Contact the next level of support.
13
The switch E_Port segmented because two fabric elements have
duplicate domain IDs.
a. Work with the system administrator to determine the desired
domain ID (1 through 31 inclusive) for both switches.
b. Notify the customer that both switches will be set offline. Ensure
the system administrator quiesces Fibre Channel frame traffic
through the switches and sets attached devices offline.
c. Set both switches offline (
Set offline state
on page 350).
i32M1022
Summary of Contents for SAN32M1
Page 1: ...IBM TotalStorage SAN32M1 Switch Installation and Service Manual GC26 7665 01...
Page 2: ......
Page 3: ...IBM TotalStorage SAN32M1 Switch Installation and Service Manual GC26 7665 01...
Page 12: ...SAN32M1 Fabric Switch Installation and Service Manual x...
Page 18: ...SAN32M1 Fabric Switch Installation and Service Manual xvi...
Page 20: ...SAN32M1 Fabric Switch Installation and Service Manual xviii...
Page 82: ...SAN32M1 Fabric Switch Installation and Service Manual 50...
Page 222: ...SAN32M1 Fabric Switch Installation and Service Manual 190...
Page 418: ...SAN32M1 Fabric Switch Installation and Service Manual 386...
Page 454: ...SAN32M1 Fabric Switch Installation and Service Manual 422...
Page 532: ...SAN32M1 Fabric Switch Installation and Service Manual 500...
Page 536: ...SAN32M1 Fabric Switch Installation and Service Manual 504...
Page 625: ......
Page 626: ...Printed in USA GC26 7665 01...