SAN32M1 Fabric Switch Installation and Service Manual
262
4
Is fault isolation being performed at the switch?
YES
NO
↓
Fault isolation is being performed at the SANpilot interface,
EFC Server, or customer-supplied server. Go to
step 7
.
5
Each port has an amber LED and a blue (2 Gbps operation) or green
(1 Gbps operation) LED adjacent to the port. The amber LED
illuminates and the blue or green LED extinguishes if the port fails.
Event
Code
Explanation
Action
080
Unauthorized world wide name
Go to
step 21
081
Invalid attachment.
Go to
step 22
.
506
Fibre Channel port failure.
Go to
step 11
.
507
Loopback diagnostics port failure.
Go to
step 12
.
512
SFP nonfatal error.
Go to
step 6
.
514
SFP failure.
Go to
step 6
.
581
Implicit incident.
Go to
step 34
.
582
Bit-error threshold exceeded.
Go to
step 34
.
583
Loss of signal or loss of synchronization.
Go to
step 34
.
584
Not operational primitive sequence (NOS) received.
Go to
step 34
.
585
Primitive sequence timeout
Go to
step 34
.
586
Invalid primitive sequence received for link state.
Go to
step 34
.
Summary of Contents for SAN32M1
Page 1: ...IBM TotalStorage SAN32M1 Switch Installation and Service Manual GC26 7665 01...
Page 2: ......
Page 3: ...IBM TotalStorage SAN32M1 Switch Installation and Service Manual GC26 7665 01...
Page 12: ...SAN32M1 Fabric Switch Installation and Service Manual x...
Page 18: ...SAN32M1 Fabric Switch Installation and Service Manual xvi...
Page 20: ...SAN32M1 Fabric Switch Installation and Service Manual xviii...
Page 82: ...SAN32M1 Fabric Switch Installation and Service Manual 50...
Page 222: ...SAN32M1 Fabric Switch Installation and Service Manual 190...
Page 418: ...SAN32M1 Fabric Switch Installation and Service Manual 386...
Page 454: ...SAN32M1 Fabric Switch Installation and Service Manual 422...
Page 532: ...SAN32M1 Fabric Switch Installation and Service Manual 500...
Page 536: ...SAN32M1 Fabric Switch Installation and Service Manual 504...
Page 625: ......
Page 626: ...Printed in USA GC26 7665 01...