447
Appendix B: Event code tables
Event Code: 208
Message:
Power supply false shutdown
Severity:
Major
Explanation:
The power supply indicated that it was about to shutdown as a result of a power loss, but never did. The
operational firmware prepared for the shutdown.
Action:
If subsequent power events occur, perform the data collection procedure for this unit using the EFC Manager,
and return the CD and the faulty power supply to IBM for analysis and repair.
Event Data:
No supplementary data included with this event.
Distribution:
Switch
EFC Server
Host
Nonvolatile
System
Event Log
System
Error
Indicator
Event Log
Call-Home
Sense Info
Link Incident
✔
✔
✔
✔
✔
✔